Injection lances

Soil stabilization

Perform injections on a selected part of the lance

PI-LONGPACK packer

Seal the injection at any depth and fix the lances

CONVENIENCE OF USE

Each element of the lance has spanner flats for a 12 / 15 mm spanner

HAMMPACK
JG-SYSTEM

Proven tools for injecting

Hammpack JG-SYSTEM injection lances, with 500mm and 1000mm solid and perforated section lengths. Balanced injection surface structure for both cement suspensions, geopolymers, acrylic gels and polyurethane resins.

Full-spectrum injection lances. Convenient to use with wrench entries (no more twisting injection lances with awkward pipe wrenches).

JG-SHOOTER

Arrowhead – allows injection directly at the ground (for solid injection lances) and/or perforated injection lances (full system compatibility). Fits JG-CONNECT-PER, JG-CONNECT injection lances.

JG-NOSHOOTER

Fixed (screw-in) blade – outlet holes allow injection along the entire length of the perforated lance at the desired section (system compatibility with full injection lance). Fits JG-END-PER injection lance.

UP TO 15 M


The maximum depth of the work carried out depends on the ground conditions, in case of favorable conditions it can be up to 15 meters.

HAMMPACK JG-SYSTEM INJECTION LANCE SYSTEM

Connection diagram JG-SYSTEM 13

JG-SYSTEM 13

Material
steel
Outside diameter
13 mm
Inside diameter
9 mm
Hole diameter
3,8 mm (JG-PER)
Holes per metre
16 (JG-PER)
Length
500 / 1000 mm
Spanner size
12 mm
Thread
G 1/4 / M10×1 (JG-END)

JG-CONNECT / JG-CONNECT-PER / JG-END-PER
JG-CONNECTOR 14 · PI-JG 18/150 · PI-LONGPACK 20/200

Connection diagram JG-SYSTEM 21

JG-SYSTEM 21,3

Material
steel
Outside diameter
21,3 mm
Inside diameter
14,3 mm
Hole diameter
5,5 mm (JG-PER 21,3)
Holes per metre
16 (JG-PER 21,3)
Length
1000 mm
Spanner size
20 mm
Thread
G 3/8

JG-CONNECT / JG-PER
JG-CONNECT-S / JG-PER-S
JG-CONNECTOR 21,3 · 3/8–1/4 · JG-HAMMPLUG 21,3

INSTALLATION OF INJECTION LANCES

1. installation of the spearhead on the injection lance:

(a) press-in tip JG-SHOOTER
b) screw-in blade JG-NOSHOOTER

2. screw in JG-HAMMPLUG


3. hammering the lance with an impact hammer

4. unscrewing the JG-HAMMPLUG

5. Fit the connector JG-CONNECTOR 14
Installation of another part of the lance.

6 In order to reach the final depth, it is necessary to

repeat steps 2-5